Helinks STS 2021-10 V 3.5.0 Quarterly Release Release Note

 

https://arn-resources.upraise.io/images/cloudARN_3224947a-1e01-49b5-8031-1674a7b148d5.png

Release Date: 30.09.2021


Helinks STS  2021-10 V 3.5.0 Quarterly Release is now available for download in the Helinks Customer Portal: Helinks Customer Portal


What is New?

Improved SCL Validation

Improved IED handling and loading

Library improvements

Improved IEC 60870-5-104 support

UI Improvements




Detailed Feature and Change Description

Improved SCL Validation


Various improvements for SCL validation and conversion


Improved IED handling and loading


Library improvements


  • Copy & Paste of Library elements in the Library Manager will now copy the backing files

  • Bay templates now correctly store the orientation of conducting equipment

  • Function and IED library elements can now be used in bus bar specification diagrams

  • Handling of logical node instance number calculation improved


Improved IEC 60870-5-104 support


  • Exposed CAA attribute in the default signal table

  • DAI creation no longer fails for specific data attributes


UI Improvements


  • Support for adding and removing logical node data instance values (DAI)

  • Support for data specification values (DAS)

  • Rotating unconnected power equipment takes effect immediately, not after deselection

  • Bay specification diagram is now closed if the bay is deleted in the single line diagram

  • Sampled value AppId was incorrectly labeled as SMV ID (in addition to the actual SMV ID)

  • Templated application groups can now override MAC addresses and AppIDs for GOOSE and SMV on a per-checkmark base

  • Editing the “Template” field of Functions and Conducting Equipment will now present a drop-down menu of existing library keys, in addition to free text editing

  • MMS Subscription (client-side initiated) now allows to choose the specific Report Application + Configuration where signal connections are created



 


The following Bugs are fixed in this Version

Priority

Key

Summary

Status

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-1006

Instantiate Bay dialog shows SubFunctions/SubEquipment in the list of optional functions

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-1004

Importing with default.pio does not resolve Conducting Equipments

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-1003

Excel export did not properly resolve 'IEC 61850 Specified' column

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-1002

Application Template Connection Matrix may erroneously declare "Sending & Receiving"

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-996

Excel import does not match existing specified LNodes with implemented imported

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-993

ApplicationRole configuration automatically includes candidates in mapping

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-991

TVoltageLevel does not properly set multiplier

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-990

New name calculation may cause collision if proposed name ends in digit

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-988

104 Address bay-wise calculation is disabled

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-985

Pasting LLN0 does not correctly pickup inst collisions with existing LLN0

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-984

Pasting LNode into SCL Functions does not correctly disambiguate inst

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-983

Touching LLN0 'inst' field forces non-empty prefix

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-982

LNode specified prefix may be overwritten by implementation prefix

Done

https://helinks.atlassian.net/images/icons/priorities/high.png

STS-973

Instantiate IED in BusBar does not instantiate related Functions

Done

https://helinks.atlassian.net/images/icons/priorities/high.png

STS-955

ComConf does not handle dataset overflow for indexed connections

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-943

Copy Paste in Library Manager does not copy Library File

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-937

Library instantiation creates default Power Equipment Functions

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-835

Equipment orientation is lost on bay template instantiation

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-595

Copy & Paste of Applications erroneously uses shared SinkItems

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-581

Instantiating LNType does not copy private fields from sclns to DataTypeTemplates

Done

https://helinks.atlassian.net/images/icons/priorities/medium.png

STS-229

Drag'n'Drop of Logical Nodes does not trigger uniqueness maintaining instance number change from edit provider

Done


Looking forward to hear your feedback.

 

Thanks,

Team Helinks STS

Powered by

Automated release notes for Jira